Defence, security and optronics
Verify multispectral sensors for protective and security applications and document their image quality.
Engineering task
A test bench needs to compare security cameras used to monitor the condition of critical infrastructure. A typical question is which features of a test specimen the visible channel shows reliably and what information a SWIR channel adds under the same test conditions.
System concept
The APQ 120/840 serves as the broadband reference optics for a laboratory setup. The calculated common image plane supports comparison between spectral channels. The visible and short-wave infrared channels use suitable detectors and filters and are aligned against the same reference specimen.
Operating scenario
Laboratory tests use reference surfaces with defined contrast and known material samples. The evaluation compares image detail, contrast and channel registration across the field. One example is inspection of protective glazing or enclosure surfaces under documented illumination conditions.
A second test series repeats the measurements after exchanging a camera or changing the ambient temperature. DGE can use the results to prepare a test report for sensor procurement or acceptance. The report documents the conditions under which the measured image quality applies.
Verification
The calculated geometric MTF provides a reference for the contribution of the optics. System performance is measured on the bench with the camera, filters and evaluation method in place.
- Image contrast on reference patterns at the centre and edge of the field
- Geometric registration of the two channels on the same specimen
- Repeatability after a camera exchange and under documented environmental conditions